Problem:
Parts tend to stick on one half of the mold.
Solution:
- Decrease injection pressure.
- Decrease hold pressure.
- Minimize cushion.
- Check for undercuts or insufficient draft.
- Stuck on the Fixed Half:
Increase close time.
Decrease Moving half temperature.
- Stuck on the Moving Half:
Decrease close time.
Decrease Fixed half temperature.