Moldflow injection molding troubleshooter and problem solver
0-Home | Flash

Problem:
Flash normally forms when the mold opens slightly during the filling or holding phase.

Solution:

  1. Ensure the mould is bedded out properly .
  2. Reduce the injection speed.
  3. Reduce the maximum cavity pressure.
  4. Reduce the melt temperature .
  5. Increase the rigidity of the mould.
  6. Increase the clamping force.